Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1224-07215
Parcel: 136371540

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-1224-07215
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/12/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/12/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
1. The design temps used for this report are for Washington National airport, please use the local design criteria 32 for winter and 104 for summer when using manual j to determine the load with next submittal. R106.1
2. Please provide the proposed equipment size and model number, and the extended ratings of the equipment. R106.1
3. Please provide the following reports from the Report Builder Tab with next submittal.
LOADS:
Component Constructions
Project Summary
DUCT:
Duct system summary
Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
12/11/2024 PDSD Application Completeness Express REVIEW COMPLETED