Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING REVISION v.3
Permit Number - TC-RES-1224-07124
Review Name: RESIDENTIAL NEW DWELLING REVISION v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/15/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/15/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-1224-07124 Revised PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL COMMENTS: A new electrical service usually serves a new dwelling unit rather than for an accessory building. A new dwelling permit would be required for renovating the shop or storage room into a dwelling unit. A trade permit is usually for repairing, replacing or relocating an existing service. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. SITE PLAN: 1. Show the location of the gas meter, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLUMBING PLANS: 1. Show each gas pipe segment sized in conformance with Table G2413.4(1). Existing gas pipes may require upgrading with this system alteration. The ¾” gas pipe shown on sheet P1 is undersized for multiple appliances. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 10/14/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |