Permit Number: TC-RES-1223-10248
Parcel: 11307168B

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-1223-10248
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/08/2024 Residential Building APPROVED
04/19/2024 Site Engineering APPROVED
04/22/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/22/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Nathan Herrera
Lead Planner

PROJECT: TC-RES-1223-10248
Address: 1401 E Hedrick Dr. Tucson, AZ. 85719
Parcel: 113-07-168B
Zoning: R-2
Existing Use: Single Family Residence
Project Description: 2nd Unit

TRANSMITTAL DATE: 04/22/2024

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence with an Accessory Dwelling Unit is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9, and 6.6.3.


1. COMMENT: PER UDC 6.3-2.B, in the R-2 zone, the allowable density is one unit per 2,904 square feet. With lot size of 5,000 square feet of second unit will not be permitted as shown. An additional unit would have to be an Accessory Dwelling Unit (ADU) and follow the ADU standards found in UDC Article 6.6.3.B.

The main ADU requirement that will be problematic for the proposed unit is; on sites where the principal structure is one story, accessory dwelling units shall not exceed 12 feet in height (UDC 6.6.3.B.4).
A Board of Adjustment Variance process will need to be applied for and approved to allow for the proposed height of the ADU as shown.
For more information on the Variance process reach out to Mark Castro at Mark.Castro@tucsonaz.gov

2. COMMENT: Per UDC Table 6.3-2.A, the required setback in the R-2 zone is the greater of 6 feet or 2/3 the height of the proposed building wall.

Based on a proposed wall height of 18 feet, the required perimeter yard setback to the north property line is 12 feet. The proposed setback is 4 feet 8 inches. Add the required setbacks to the site plan on the next submittal.
The proposed ADU encroaches into the required side yard setback.
A Design Development Option must be applied for and approved before this permit can be approved by Zoning.
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf
For more information about the DDO process contact Wyatt Berger at wyatt.berger@tucsonaz.gov
3. COMMENT: As the proposed height of the ADU will require a Variance process, the setback reduction can be processed through the Variance process instead of the DDO process.
If the ADU can be redesigned to be in conformance with the maximum 12 feet standard, only the DDO process will be required to reduce the setbacks.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov.
03/21/2024 PDSD Application Completeness Express REVIEW COMPLETED