| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/10/2024 | Site Engineering | NOT REQUIRED | |||
| 12/18/2023 | Site Zoning | NOT REQUIRED | |||
| 01/10/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/28/2023 | Residential Building | REQUIRES RESUBMIT | Identify the function of the spaces on each side of the damaged wall. A window may not separate the garage from dwelling space. 1. Show the door from a garage to dwelling with a 20-minute fire rating (or 1-3/8” solid core) with self-closing and self-latching provision, R302.5.1. 2. Show a ½” gypsum board (garage side) on all walls common to the garage and house or other fire rated product in compliance with R302.6. |
||
| 12/15/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |