Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-1223-10075
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/14/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/14/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1223-10073 (455 W MCIVER PL TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. The overhead service conductor over the structure requires an 8’ clearance above the roof, E3604.2.1. Show a mast height necessary to achieve this clearance. 2. Show and provide a panelboard clear working space of 30” wide x 36” deep, E3405.2. Update the site plan to also show the correct location of the service entrance on the building, or is the service entrance being relocated? Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 12/14/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |