Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1223-10012
Parcel: 124120210

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.3

Permit Number - TC-RES-1223-10012
Review Name: RESIDENTIAL SIMPLE REVIEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/02/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1223-10012 (1148 E BROADWAY BL TUCSON, AZ 85719)
2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. The 14’ of ½” pipe (Segments GH), is undersized for the given demand(90,000 BTUh) and length(76’). See Table G2413.4(1). 3/4” is minimum size required.
2. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. ½” BIP at 76’ can only supply 56,000 BTUH per Table G2413.4(1).

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
01/02/2024 PDSD Application Completeness REVIEW COMPLETED