Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-RES-1222-01734
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/25/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/25/2023 | Residential Building | REQUIRES RESUBMIT | Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). A gas template is available at https://www.tucsonaz.gov/pdsd/residential-permits A total demand of 135,000 Btu with total developed pie length over 60 feet requires a 1" pipe. |
||
| 01/22/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |