Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1222-01725
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/02/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/02/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-1222-01725 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Each dwelling unit with kitchen requires a separate Pima County assigned street address, R319. Notate each dwelling address on the plans. SITE PLAN: 1. Update the electric and water lines from property line to building, R106.1.1. Show all utility point of connections without dependance on another dwelling. 2. Show a street address for each dwelling on the site plan, R319. 3. Show the square footage of living space, garage and covered patios, R106.1.1. PLANS: 1. Designate all walls for proposed replacement. 2. Show appropriate fire rating of altered or repaired common walls separating the dwellings, R106.1. SECTIONS - DETAILS: 1. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). 2. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation or need for providing air-impermeable rigid insulation at the roof, R806. 3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing as a part of minimum total insulation value, R806.5. PLUMBING PLANS: 1. Show appropriate water, drain and vent pipe sizes, P2903.7. MECHANICAL PLANS: 1. Show location and size of proposed equipment and duct replacement, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Provide a wiring diagram and panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 01/05/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |