Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-1222-01721
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/11/2023 | Zoning Modifications - DDO | APPROVED | |||
| 05/05/2023 | Zoning Modifications - Variance | NOT REQUIRED | |||
| 07/11/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/23/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-1222-01721 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet Zoning and other departmental requirements, conditions and concerns before permit approval. PLANS: 1. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. 2. A roof projection may not extend closer than 24” to the neighboring property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). Update the garage roof overhang for compliance. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Update keynote #8/A4.0 and detail #15/A7.0. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
||
| 05/30/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-1222-01721 441 S Stratford Dr. – R-1 Bedroom, Garage & Workshop Addition (2nd Review) TRANSMITTAL: May 30, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As wall heights were not provided from design grade Zoning has added 6” to the provided heights to determine perimeter yard setback requirements. 1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height 11’-6” the required perimeter yard setback from the proposed addition to the southeast property line is 7’-8”, proposed setback is 3’-11”. Based on a wall height 9’-7” the required perimeter yard setback from the proposed addition to the northwest property line is 6’-5”, proposed setback is 1’-0” to 5’-5”. 2. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Based on a wall height 9’-7” the required front street perimeter yard setback from the proposed garage addition to the front street property line is 20’-0”, proposed setback is 12’-11” to 15’-8”. 3. The minimum setback to the back of a sidewalk for a garage is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a garage is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b.). As there are no sidewalks based on a Zoning Administrators determination the minimum distance for a parking space is 18’ from garage to street property line, proposed parking space distance is 12’-11” to 15’-81”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. Additional comments that need to be addressed prior to applying for the required Board of Adjustment: 4. This comment was not addressed. Provide a dimension from the centerline of Stratford Drive to the face of curb and from the face of curb to the street property line. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 04/28/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |