Permit Number: TC-RES-1222-01721
Parcel: 129024300

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-1222-01721
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/28/2023 Residential Building REQUIRES RESUBMIT Provide a complete plan set for Building review. Separate construction plans from support documents.
04/17/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-RES-1222-01721
441 S Stratford Dr. – R-1
Bedroom, Garage & Workshop Addition (2nd Review)

TRANSMITTAL: January 12, 2023

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

As a reduced parking space length is proposed in front of the proposed garage addition a Board of Adjustment for Variance is required, see UDC Article 3.11.1.B.4. All other setback reductions can be processed through the same Board of Adjustment process. The following comments apply.
Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As wall heights were not provided from design grade Zoning has added 6” to the provided heights to determine perimeter yard setback requirements.

1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height 11’-6” the required perimeter yard setback from the proposed addition to the southeast property line is 7’-8”, proposed setback is 3’-11”. Based on a wall height 9’-7” the required perimeter yard setback from the proposed addition to the northwest property line is 6’-5”, proposed setback is 3’-0” to 5’-5”.

2. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Based on a wall height 9’-7” the required front street perimeter yard setback from the proposed garage addition to the front street property line is 20’-0”, proposed setback is 18’-0” to 18’-6”.



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
03/28/2023 Zoning Modifications - Variance REQUIRES RESUBMIT Zoning has identified an item that requires a variance. A Board of Adjustment Variance is processed in accordance with UDC Section 3.10.3. As such, a pre-application meeting and neighborhood meeting is required prior to the submittal of an application. To request a pre-application meeting, please apply for "Pre-Application Conference" at TDC Online under your permit #. If you have questions, you can email me at Georgia.Pennington@tucsonaz.gov
03/20/2023 Fire New Construction REVIEW COMPLETED
03/16/2023 PDSD Application Completeness Express REVIEW COMPLETED