Permit Number: TC-RES-1222-01596
Parcel: 116141150

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1222-01596
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2023 Site Engineering NOT REQUIRED
12/28/2022 Site Landscape NOT REQUIRED
01/25/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/25/2023 Residential Building REQUIRES RESUBMIT TC-RES-1222-01596

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.

SECTIONS - DETAILS:

1. Notate the wall details on sheet SD1 with a 6” minimum separation of exterior siding or sheathing above finished grade, R317.1 item 5. Also, show the weep screed with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1.
2. Show an unvented roof assembly with all insulation at the roof including an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing as part of the total R-30 insulation requirement, R806.5.
3. Show wall insulation, N1102.1.

ELECTRICAL PLANS:

1. Remove the future range/oven circuit (#10/12) as the permit does not approve a dwelling unit which requires a Zoning approval, an issued address and impact fee collection.
2. Update the Riser Diagram showing the new 100 AMP subpanel with feeder size.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
(520) 837-4912 PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
01/11/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-RES-1222-01596
632 N Calle Zapata - R-1
Convert Carport to Second Dwelling Unit (1st Review)

TRANSMITTAL: January 11, 2023

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

1. Provide a lot coverage calculation on the plan. Review UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, and provide a correct lot coverage calculation.

2. Based on information shown on sheet E-1, new range & oven, you are proposing a 2nd dwelling unit. Based on a lot size less than 10,000 sq. ft. the site does not support 2 dwelling units. This could be permitted as an Accessory Dwelling Unit (ADU) but the plans would need to be modified compliance with UDC Articles 4.9.7.B.6, 8, & 9 and 6.6.3. Also, Impact Fees will apply if you elect to proceed with the ADU. If you elect to develop this as a sleeping quarters all references to a Kitchen, range & over, applicances will need to be removed from the plans.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
12/27/2022 PDSD Application Completeness Express REVIEW COMPLETED