Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1222-01527
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/13/2023 | Site Engineering | NOT REQUIRED | |||
| 02/27/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/27/2023 | Residential Building | REQUIRES RESUBMIT | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Each dwelling unit with kitchen requires a separate Pima County assigned street address, R319. Notate each dwelling address on the site plan (or remove cooking appliances). SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Each dwelling requires an independent utility shut off device Identify the utility lines requiring upgrade or replacement. 2. Show a street address for each dwelling on the site plan, R319. PLANS: 1. Show all alterations of the existing space for achieving a second independent dwelling unit. SECTIONS - DETAILS: 1. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed dwellings and show an appropriate water meter size. 2. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1. MECHANICAL PLANS: 1. Clarify if any changes are proposed. ELECTRICAL PLANS: 1. Provide a Riser Diagram showing an independent disconnect for the proposed dwelling with a feeder size, NEC 225.30 and E3403. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 02/21/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-1222-01527 110 N Melwood Av – R-2 Second dwelling unit (1st Review) TRANSMITTAL DATE: February 21, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Per UDC Table 6.3-2.A: Dimensional Standards for the R-1, R-2, R-3, MH-1, & MH-2 Zones, maximum residential density within the R-2 zone is 15 dwelling units per acre (2,904 square feet of lot area per unit). Based on a lot size of 5,200 square feet according to the Pima County Assessor’s Office, a second dwelling unit is not permitted on this lot. However, an accessory dwelling unit (ADU) is permitted on this lot, subject to use-specific standards 4.9.7.B.6, .8, and .9, and 6.6.3. Review the aforementioned use-specific standards. Show the location of the required motor vehicle parking space or demonstrate the parking space requirement can be waived through UDC 6.6.3.B.2. 2. The Zoning Review Section was unable to determine whether a zoning compliance review was submitted and completed for the perimeter wall constructed around 2019. Either provide permit documentation or apply for a separate fence/wall permit through the Tucson Development Center Online. If you have any questions about this transmittal, contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 02/08/2023 | NPPO | REVIEW COMPLETED | |||
| 02/07/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |