Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-1222-01527
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/03/2023 | Site Zoning | APPROVED | |||
| 04/04/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/04/2023 | Residential Building | REQUIRES RESUBMIT | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Each dwelling unit with kitchen requires a separate Pima County assigned street address, R319. Obtain the new address and notate each dwelling address on the site plan. SITE PLAN: 1. Each dwelling requires an independent utility shut off device, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLANS: 1. Show all alterations of the existing space for achieving a second dwelling unit with independent utility connections such that each dwelling may function without utilities supplied from the other dwelling. SECTIONS - DETAILS: 1. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). Notate the means of achieving the fire spread control with required materials including alteration of existing separating walls. PLUMBING PLANS: 1. Show an individual accessible water supply shut off and separate water heater for the proposed (ADU) dwelling unit, P2801.1 and P2903.9.1. ELECTRICAL PLANS: 1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. GFCI protected, E3902.6. 2. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 3. Show one 20 AMP branch circuit in the laundry area; this circuit may not serve other locations, E3703.3 and 3901.8. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 03/20/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |