Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1222-01400
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/26/2022 | Site Engineering | NOT REQUIRED | |||
| 12/28/2022 | Site Landscape | NOT REQUIRED | |||
| 01/23/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/23/2023 | Residential Building | REQUIRES RESUBMIT | 1. Provide a landing with minimum 36” depth between the door and tread at the bottom of the stairway, R311.7.6. 2. Specify the minimum thickness (1/2”) of non-structural (T1-11) siding, R602.10.3.4. 3. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. 4. Show wall and ceiling insulation. Ceiling insulation may be reduced to R-30 for limited areas with insulation placed above top plates, N1102.2.2. |
||
| 01/09/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-1222-01400 1723 W Pueblo Vista Bl - R-1 Porch Enclosure (1st Review) TRANSMITTAL: January 9, 2023 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. The plot plans shall show all structures that are on site to include any sheds or batting cages that are on site. Based on aerial photo there is a shed structure along the west property line and what appears to be a batting cage along the south property line. Show these structures on the plan and include them in the lot coverage calculation. Provide approve permit or compliance review documents with the next submittal or include these structures in this permit. It does not appear that these structures meet perimeter yard setbacks of 6’-0” or 2/3 the height of the exterior wall, greater of the two. Per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 2. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, to include but not limited to: a. Property dimensions. b. Owners name. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 12/23/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |