Permit Number: TC-RES-1222-01397
Parcel: 140231240

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1222-01397
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/13/2023 Site Engineering NOT REQUIRED
01/17/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/17/2023 Residential Building REQUIRES RESUBMIT Provide a complete plan set for review. Include sheet #2, 3 & 4.
01/13/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-RES-1222-01397
5918 S Southland Bl - R-2
Addition (1st Review)

TRANSMITTAL: January 13, 2023

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2), subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

1. Zoning was not able to find approved permit documents for the “EX-RAMADA, EX-AWNING/GARAGE & EX-STG”. Based on the square footage of the “EX-RAMADA & EX-AWNING/GARAGE” building permits are required. Based on the square footage of the “EX-STG” Zoning compliance is required. Either provide approved building permits and zoning compliance with the next submittal or include these structures in this permit. Provide wall heights for these three structures. Per UDC Article 6.6.3.D Accessory structures, except for accessory dwelling units, shall not exceed 12 feet in height, unless attached to a principal structure. Also, per UDC Article 6.6.3.E The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement. Clearly demonstrate that the above requirements are not exceeded. Once the comment is addressed additional comments maybe forth coming.

2. Provide building elevations with the next submittal. These elevations shall in include wall height dimensions from design grade to the highest point of the wall, Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

3. Based on the “10’-0” TOP OF PARAPET WALL” provided on the plan the required perimeter yard setback from the proposed addition to the north property line is 6’-8”, proposed setback is 4’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
01/13/2023 PDSD Application Completeness Express REVIEW COMPLETED