Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1222-01247
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/13/2023 | Site Engineering | NOT REQUIRED | |||
| 02/09/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/09/2023 | Zoning Modifications - DDO | PENDING ASSIGNMENT | |||
| 01/17/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-1222-01247 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. PLANS: 1. Show the proposed building dimensions. SECTIONS - DETAILS: 1. Show a cross-section detail for the new exterior wall, R106.1.1. Show the minimum 12” footing depth below the undisturbed ground surface with 12” minimum width for wood framed walls with minimum of one #4 rebar in the proposed continuous footing, R403.1. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5) with minimum ½” diameter anchor bolt and treated sill plates, R602.10.8 & R403.1.6. . 3. Clarify the placement of any ceiling/roof and wall insulation for determining the need for including an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing as part of the total insulation requirement, R806.5. MECHANICAL PLANS: 1. Show any heating, cooling or ventilation systems. ELECTRICAL PLANS: 1. Show any electrical outlets or devices. 2. Show a switch controlled light at the room entrance, E3903.3. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 02/08/2023 | Site Zoning | REQUIRES RESUBMIT | Please resubmit the DDO application under T22CM07387 | ||
| 01/13/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |