Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-1126-06186
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/09/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/09/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comments: 1) Show if water heater and/or the backup generator will be new appliances on this permit or verify if work is "plumbing only". Replacements and modifications of equipment must comply with the IRC and must be approved prior to installation. 2) The generator exhaust must be 10 feet (3048 mm) from the property lines; 3 feet (914 mm) from exterior walls and roofs; 10 feet (3048 mm) from operable openings into buildings; 10 feet (3048 mm) above adjoining grade. Please show distances adhering to IFGC 501.3.1 3) Provide manufacturer specifications of the pool heater replacement, if applicable. |
||
| 11/06/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | Completeness check done |