Permit Number: TC-RES-1126-06133
Parcel: 126160160

Review Status: In Review

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1126-06133
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
N/A Bldg Permits - Post Review Express PENDING ASSIGNMENT
N/A Residential Building PENDING ASSIGNMENT
11/10/2026 Residential Engineering REQUIRES RESUBMIT Site Engineering Review

TC-RES-1126-06133
101 S LA CRECIENTE
Date of Transmittal: 11/10/2026
Description: CONVERT PRIMARY RESIDENCE TO A DUPLEX…

City of Tucson Code:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

City of Tucson Inclusive Home Ordinance 10463
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf

Site Engineering comments are as follows:

1. Provide a site plan with the accessible route drawn, dimensioned, and labeled. Ensure it meets the requirements set forth in the City of Tucson Inclusive Home Ordinance 10463, including a minimum 4-ft width. The Accessible Route should connect an accessible entrance of each unit to a driveway, sidewalk, or the right of way.
2. Describe the composition of the Accessible Route to the ADU’s main entryway. Permissible construction materials and finishes include:
• Portland cement concrete, four inches thick, with a smooth or broom-finish;
• Brick Pavers set in a bed of cement;
• Resin Pavement Mixture that complies or is equivalent to ASTM D 4123;
• Any surfaces equivalent in smoothness, hardness, and durability.
• NOTE: Decomposed granite or similar is not acceptable.
3. Provide the proposed slopes for the accessible route. The running slope of the accessible path must not exceed 5% or 1:20 (as included in the note), and the cross slope must not exceed 2% or 1:50.
4. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles.

*Please submit revised drawings along with a detailed response letter stating how each resubmittal comment has been addressed*

To re-submit, visit the Tucson Development Center Online at:
https://cityoftucsonaz-energovweb.tylerhost.net/apps/selfservice#/home

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov
11/13/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston, Planner

PROJECT: TC-RES-1126-06133
101 S La Creciente. Tucson, AZ 85711
SFR Convert to Duplex w/Attached Pergola (1st Review)

TRANSMITTAL DATE: 11/13/2026

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. The proposed pergola will require a variance per Unified Development Code (UDC) 3.10.3. as Sheet A-0.0 shows no setback from the north street-side property line. Per Unified Development Code (UDC) 6.4.5.C.1.b., from other than the front lot line, the street perimeter yard is 10 feet as measured from the north property line in this instance.

To submit an application for a Board of Adjustment Variance requesting a complete variance from the required 10’ side setback, please visit www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-2 .

2. Please correct the following:
a. On Sheet A-0.0, the 5’ rear and south side setbacks are for all residential structures, not only ADUs as indicated on the site plan.
b. On Sheet A-0.0, please note that the attached pergola is not considered in the Lot Coverage calculations, nor do any porches that are not used for utilities.
c. On Sheet A-0.1, please list the preferred water method for the landscaping.

3. For the resubmittal for permit TC-RES-1126-06133, please submit the following:
a. Board of Adjustment Decision Letter
b. Revised site and landscape sheets
c. Response letter addressing all staff comments.

4. A secondary dwelling requires to be separately addressed. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the unit numbers. Note, a resubmittal and address change are required and the unit number(s) must be listed on all sheets.

5. Residential zoning has acknowledged this property has a structure on-site with a with ‘contributing status’ with the National Register of Historic Places and advises the owner to contact the State Historic Preservation Office (HPO) to determine if this project will impact the status. Contact https://azstateparks.com/SHPO for more information. This comment is purely made as a courtesy as there may be tax implications. No action is required and is at the discretion of the owner.

6. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

The City of Tucson Unified Development Code may be accessed here: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-1

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov
11/09/2026 PDSD Application Completeness Express REVIEW COMPLETED Completeness Check Done