Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-1125-05726
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/23/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/23/2025 | Residential Building - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-1125-05726 ADDRESS/PARCEL: (2521 E HELEN ST TUCSON, AZ 85716) Submit your revised reports along with a response letter which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Please show the location of the electric service panel that will supply power to the accessory structure and the proposed electrical run and connection point on the site plan (R106.1.1). 2. Please provide and electrical plan showing the number and location of outlets and receptacles. Include the mini-split details. You can refer to the last page of the following sample as a reference: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/addition_sample.pdf 3. Per City of Tucson Amendments to the 2018 IRC, structures must have a 6’ fire separation distance OR the affected walls must have a 1 hour fire rating (R302.1). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2018_-_irc_amendments.pdf 4. Please resubmit. Should you have any questions about these comments, I can be reached at ian.gillaspie@tucsonaz.gov. |
||
| 12/12/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-1125-05726 2521 E Helen St., Tucson, AZ 85716 Shed (1st Review) TRANSMITTAL DATE: 12/12/2025 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Although the site plan provided contains some of the information needed for a zoning review, this plan is insufficient for a zoning review and the aerial overlay is unnecessary and is not lined up with the lot lines as aerial Pictometry shifts every time images are taken. Resubmit a new site plan. A site plan template and requirements of what needs to be listed on the site plan can be found at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example Below are a few examples of what a site plan should contain: a. an engineer scale to the site plan (no need for the site map and image). For example, 1” = 10’. b. north arrow c. name and address of owner(s) d. lot’s legal description: Blenman E20’ Lot 11 W40’ Lot 12 Blk 7 e. lot’s overlay zone: Blenman-Elm f. zoning of the lot and zoning of adjoining lots g. all structures, their square footage (except for the pool), and their uses h. lot coverage per Unified Development Code (UDC) 6.4.3. – the total square footage of enclosed structures and vehicle maneuvering areas divided by the square footage of the lot. i. Utilities j. distances between the shed and the property line (s) and the residence. 1. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 12/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |