Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-1125-05724
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/05/2025 | Residential Engineering | NOT REQUIRED | |||
| 12/17/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/17/2025 | Residential Building - Standard | REQUIRES RESUBMIT | Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Facilitate a shorter back check time: provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. 1. Self-closing and self-latching provision, R302.5.1. Ensure the door from the garage to the utility room is also self closing. 2. 5 Show garage opening narrow panels with fastening details using a prescriptive method at Figure R602.10.6.2, R602.10.6.3 or R602.10.6.4. Wood stud shear wall elevation note 2 & 3 calls out the shear wall schedule but there is none, add the schedule or remove note. 3.2. Garage Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage and detached garages with service, E3703.5. A receptacle is required at each vehicle bay not more than 5.5 feet above the floor, E3901.9. Additional receptacles are optional. |
||
| 12/12/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-1125-05724 3045 W Calle Gardenias, Tucson, AZ 85745 Attached Garage Addition (1st Review) TRANSMITTAL DATE: 12/12/2025 This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence is a permitted use in this zone (Table 4.8-1). RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. The total square footage of the vehicle use area has not been added to the plan. Per UDC 6.4.3.B.3.b, vehicle use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are used to determine lot coverage. Please include all vehicle use areas and recalculate the total lot coverage. 2. Sheet A01 is included in the plan set two times. Please leave the sheet not signed by the neighbor out of the next submittal. 3. Please ensure Sheet A01 containing the neighbor signature is clearer in the next submittal as it is blurred. 4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 12/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |