Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.3
Permit Number - TC-RES-1125-05623
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/05/2026 | Residential Building - Standard | APPROVED | |||
| 03/05/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/03/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-1125-05623 4041 E WHITTIER ST New addition to existing single-family residence. (3rd Review) TRANSMITTAL DATE: 3/3/25 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. Comment 1: Please draw, label, and dimension the wall height(s) of the proposed addition from design grade to top of wall on the elevation drawings on pages A2.0 and A3.0. Also include labels and measurements for the total building height of the existing structure, the projected roof fascia, and the proposed addition. Information on both the shorter outer walls and taller inner walls should be included. These measurements should be provided in addition to the existing ‘bottom of framing’ measurements on the plans. Comment 2: Correction from submittal one comment(s), re:DDO: As the proposed addition is new construction, it needs to meet current setback requirements to be approved by right. Based on the provided site plan, the setback appears to match the setback of the existing home of 2’ between property line and structure. A Design Development Option (DDO) will be needed for the approval of a reduced setback. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf. For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 02/18/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |