Permit Number: TC-RES-1125-05618
Parcel: 125121410

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1125-05618
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/10/2025 Residential Building - Standard NOT REQUIRED
12/10/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/01/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-1125-05618
Location: 925 N CAMINO MIRAMONTE
Review Date: 12/1/2025
Site Engineering Comments:

1. This property resides within Christmas Wash floodplain and will require a floodplain use permit. This will require the submission of a Floodplain use permit with elevation certificate. Please start a new FPU at our permit application web page: https://tdc-online.tucsonaz.gov/#/home The FPU permit is a separate permit that can be submitted within the sub-records tab of this building permit on TDC online.

2. For the shed, flood venting will be required according to Tucson Code PART II Chapter 26, Section 26-11.2.(8). For resubmission of the residential building permit and submission of the flood plain use permit, have the flood vents and a detail shown on the construction plans. Have the detail include dimensions of vents as well as height above grade.

3. For flood venting a minimum of two openings will be required. The vents will have a total net area of not less than one square inch for every square foot of enclosed area. Openings may be equipped with screens, louvers, valves, or other coverings or devices if they permit the automatic entry and exit of floodwater.

4. Due to the flood venting requirement, the floodplain use permit process will include elevation certificate to verify the construction and placement of the flood vents.

5. Site engineering is unable to approve this permit until the Floodplain Use Permit has been issued.

If you have any questions or concerns, please contact
Corey Hines
Corey.Hines@TucsonAZ.gov
12/09/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston, Planner

PROJECT: TC-RES-1125-05618
925 N Camino Miramonte., Tucson, AZ 85716
Front Yard Shed (1st Review)

TRANSMITTAL DATE: 12/09/2025

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Per UDC 6.6.3.C., detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, with exceptions which do not include sheds. Approval from UDC 6.6.3.C must be obtained through a Board of Adjustment variance before the permit can be approved by Zoning.

Please submit an application for a Board of Adjustment Variance requesting that the shed be in front of the primary residence: www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-2

2. Please include the BofA decision letter with the resubmittal packet. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

The Unified Development Code can be found at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
11/26/2025 PDSD Application Completeness Express REVIEW COMPLETED