Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1125-05574
Parcel: 136340480

Address:
7642 E DAVID DR

Review Status: In Review

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1125-05574
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
N/A Bldg Permits - Post Review Express PENDING ASSIGNMENT
N/A Residential Building - Standard PENDING ASSIGNMENT
12/03/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-1125-05574 – Residential Building – Shed
7642 E DAVID DR TUCSON, AZ 85730 (R-1 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: December 03, 2025

This site is in the R-1 Residence Zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 for 1 unit; 4.9.7.B.1 - .9, & .11 for 2 units (min. 10,000 sq ft lot size required).

Plan review for the above referenced shed has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:
The scope of this plan review covers zoning, use(s), legal description, adjacent properties, setbacks (building or wall heights), dimensional standards, property permitting history, density (units/lot size), and lot calculation (enclosed building and structure, parking, and driveway versus overall lot size) requirements. All code references are to the Tucson, AZ Unified Development Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PLANS AND ELEVATIONS OR DRAWING SET:

1. COMMENT: The site plan provided is incomplete.

a) Provide a site plan that meets the requirements show in the plot plan example at the following link:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example

More Specifically:

1) Draw, label, provide heights and dimension every existing and proposed structure on-site to a scalable drawing graphic. Additionally, provide dimensions of any structure as it relates to nearby structures and property lines.

Draw and label all setbacks. Setbacks for side and rear property lines are 6’ or 2/3 the height of any structure flanking the south, west and east property lines, whichever is distance is greater. The front yard setback is 20’-0”.

Be sure to include vehicular use areas (driveway, parking spots), sidewalks and even ‘open’ structures like porches, shade structures, carports, if applicable.

Label everything that exists on the property (walls, fences and provide heights measured from above finish grade at various locations along the fence/wall) if applicable.

2) To complete missing information (legal description, subdivision name, book and page numbers, township-section and range) on the plot plan example, refer to Pima County’s website https://gis.pima.gov/maps/detail.cfm?&parcel=136340480

3) Update site plan (property lines, property line lengths) to be reflective of information on Pima County’s website. See https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=19059

4) Measure square footage of every enclosed structure on site and driveway/vehicular use area and input into lot coverage calculation table.

5) Update the primary residence graphic to be representative of reality via Pima County’s website https://www.asr.pima.gov/ParcelData/prc/13634/0480.pdf

6) Label front street (E David Rd).

7) Provide missing dimension from centerline of E David Rd to curb (per provided plot plan sample).

8) Provide missing dimension from curb to property line (per provided plot plan sample).

9) Draw and dimension driveway and any other parking spaces or areas serving as a vehicular use area.

10) Provide missing zoning labels on all four sides of this parcel including this parcel (including this parcels zoning, R-1).

11) Provide missing site plan scale and corresponding graphic scale.

2. COMMENT: Per TABLE 6.3-2.A of the UDC (referenced below), the perimeter yard setback(s) along the west and south property line(s) are 6’ or 2/3 the height of the utility shed, WHICHEVER DISTANCE IS GREATER. As currently shown, and assuming the brick wall is inside both property lines, the setbacks are not being met. See below for a potential resolution:

a) 1’-0” or more or 1-0” OR Less (encroaching in setback):
Secure a neighbor setback waiver (provided below) signed and dated by the property owner(s) to the west and south (across the street / alley):

(Neighbor Waiver Sample – Copy and Paste, exactly as shown, onto Site Plan):

My Name is __________________ and I am the owner of the property located at
________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan.

Signature: _______________________ Date:___________________________

Mi hombre es ________________ y yo soy el dueño de la propiedad ubicada en la
_____________________. He revisado el plan y no tengo ninguna objeción a que
estructura se encuentra o construye ____________ desde la línea de propiedad,
como se muestra en el plan.
Firma: _________________________Fecha: ________________________________

b) 1’-0” or more from property line and unable to obtain neighbor waiver:
Should you be unsuccessful in your attempt to retrieve the neighbor waiver there is a Design Development Option (or DDO) which affords an attempt to seek relief from the setback requirements. Know this is an extra 6-week review and the neighbors within 100’-0” are made aware of this attempt to seek relief from being in the setback. Zoning will not be able to approve the permit application until the DDO is approved. This information is linked here:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3

To submit a DDO application, apply for a new sub-record under this permit at TDC Online.

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

See below for more information on the DDO process.

c) Less than 1’-0” from property line and unable to obtain neighbor waiver:
Should you be unsuccessful in your attempt to retrieve the neighbor waiver, a board of adjustment variance will be required to permit the utility shed as shown on the site. See variance requirements below. Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved.

See below for more information on the B/A Variance process.

3. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments.

Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration .
Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov

DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration . Note that multiple DDO’s can be submitted concurrently on the same application.

To submit a DDO application, apply for a new sub-record under this permit at TDC Online. In order to get this specific review scheduled and if you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. Zoning cannot approve the zoning review portion of the permit until the DDO has been approved.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit
2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.
3. Resubmit ALL documents (all drawings in sheet index)

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .