Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1125-05546
Parcel: 126151840

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.2

Permit Number - TC-RES-1125-05546
Review Name: RESIDENTIAL ADU v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/31/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/30/2025 Residential Building REQUIRES RESUBMIT TC-RES-1125-05546
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. The 2024 IRC will be in effect Jan 1, 2026.

The proposed dwelling does not qualify for an Accessory Dwelling Unit with a maximum 1000 SF size. A structure (including a dwelling) area is measured from exterior footprint of each floor. This building includes 1397 SF of floor area determined from the dimensions on the plans.

Reduce the dwelling area or relabel the title blocks on each sheet of the plan set. Update the square foot area shown on sheet E1.1 and M1.0 for total floor area using exterior structure dimensions.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

GENERAL COMMENTS :
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Sustainability-Codes

1. Plans submitted for a newly constructed one- or two-family dwelling require compliance with design ordinances for handicap, photo-voltaic, gray water, and EV charging preparations. Design Ordinances adopted by the City of Tucson.
2. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc.
3. Plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 .
a. Show a minimum 300 SF clear solar-ready zone on a roof or framing plan, T103.3. Model plans should show four typical south facing roof surfaces.
b. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9. Provide a future PV breaker space at the last panel space.
4. Plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, require gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Include two clothes washer standpipes, one with an above grade stub-out, and one to the building drain; also provide gray drain-line discharge of all second story bathing fixtures through an exterior-wall drop for future gravity distribution. Include an aliened purple colored 2” or 3” vertical drop to a cleanout cap 2’ above grade. Add the appropriate detail found at the web site: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations
5. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space.
6. Field welding requires a completed special inspection request form for review with the permit plans, R109.2. Obtain an inspector and provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections.

SITE PLAN:
.
1. Each dwelling building requires a street address assigned with a Pima County application, R319. Show Pima County assigned unit numbers at each dwelling on the site plan.
2. Show a minimum 3” sewer clean out at keynote #17 and show the connection point to the existing property sewer line, R106.1.1.

PLANS:

1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1.
2. Provide a header schedule or identify compliant header sizes supporting the roof consistent with Table 502.5(1) & R602.7(1).
3. Show a beam size with appropriate load carrying capacity for the second level near the stairway, R301.1.

PLUMBING PLANS:

1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe and water meter size.
2. Show the water heater rating, P2801.1.
3. Show a separate sheet number for each plumbing page.

MECHANICAL PLANS:

1. Show bathroom (without a window) exhaust fan locations with minimum 50 CFM rating, R303.3 and M1505.

ELECTRICAL PLANS:

1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location should be coordinated with TEP for approval.
2. Provide the Electric Vehicle Supply Equipment 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle and label the circuit “EV Ready” and locate the receptacle at a parking area, N1104.2.1. Include the Electric Vehicle load entry (typically 7680 watts) in the electrical load calculations (continuous demand) like the HVAC entry, N1104.2.2.
3. The dishwasher/disposal may use a single 20A circuit, E3703.7 amendment.
4. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3.

OUTDOOR LIGHTING CODE

1. Provide full cut-off FCO style fixtures or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining compliance within exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
12/23/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-1125-05546
Location: 402 S JERRIE AV Unit: UNIT 2
Review Date: 12/23/2025
Site Engineering Comments:
1. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/
2. Refer to Technical Standards Manual Section 7-01.4.3 for sidewalk specifications including the minimum 4ft-width and composition minimums.
3. In accordance with Colonia Allegre Subdivision final plat, there exists a 5-ft utility easement along the West property boundary. It is required that this easement is shown/called-out on the provided site plan. It should be noted that encroachment into said easement requires approval from all associated companies that maintain ownership of said easement.
If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
12/31/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-RES-1125-05546
402 S Jerrie Av, Unit 2, Tucson, AZ 85747
ADU (2nd Review)

TRANSMITTAL DATE: 12/31/2025

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

The site plan on Sheet AS1.0 is missing some of the information required for a full Site Zoning review. The requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example Below is a list of requirements specific to your project.

1. Please show the zoning of the surrounding properties.
2. Provide the lot dimensions on Sheet AS1.0. This information can be found at the Pima County Assessor’s website, here: www.asr.pima.gov/ParcelData/Map/Arm/MP09/09040_03.PDF
3. Show the vehicle use area for the principal residence
4. Show the distance from the main residence to the front and side property lines.
5. Keynote 2 on Sheet AS1.0 indicates a setback line just north of the ADU. This is an incorrect line; the 5’ setback line for the ADU runs parallel to the property line and is then 10’ where it intersects with the 20’ front property line.
6. Per the Paving Plan for Jerrie Ave., https://maps-and-records.tucsonaz.gov/construction-plans/details/I-62-014_02 , (I-62-014_002) Provide the measurement from the centerline of Jerrie Ave to the front property line (30’).
7. Provide the measurement from the centerline of Jerrie Ave to the back of curb (17’).
8. Provide the distance between the front of the curb and the property line. (8’)
9. Show and note on Sheet AS1.0, for example, the dust free ADA 4’ – wide sidewalk leading from the front door of the ADU to the public right-of-way (see Site Engineering Comment 2).
10. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
12/22/2025 PDSD Application Completeness Express REVIEW COMPLETED This permit is for one ADU. The 2nd ADU will have to done with another permit.