Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-1125-05478
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/13/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/13/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | PDSD Residential Review Section PROJECT: TC-RES-1125-05478 EMERGENCY GAS RECONNECT.-(1st Review) (2944 N GERONIMO AV) TRANSMITTAL DATE: November 13, 2025 1) The 1/2” main line pipe is undersized for the given length (97') and total appliance demand (100,000BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. Please resubmit a gas piping template showing an adequate main pipe size sufficient to feed all appliances. Please email any questions to: PDSD-Residential@tucsonaz.gov |
||
| 11/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |