Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1125-05349
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/13/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/07/2025 | Addressing Validation | REQUIRES RESUBMIT | The permit and plan show to be for two Accessory Dwelling Units (ADU) and requires to be separately addressed. Each ADU requires a separate address. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to assign/add the units or a new address for these ADUs. Please resubmit your plans and all supporting permit documents to reflect the updated address, in addition, a change of address request will need to be submitted in order to properly update the location of this permit. For questions: PDSD-Residential@tucsonaz.gov | ||
| 11/13/2025 | Residential Building | REQUIRES RESUBMIT | TC-RES-1125-05349 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. The 2024 IRC will be in effect Jan 1, 2026. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. Show Pima County assigned unit numbers at each dwelling on the site plan. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. SITE PLAN: 1. Clarify the electric line from the sewer line, R106.1.1. PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include all threshold conditions for a route from the exterior into the living space. 3. Individual dwelling units require separation with a 1-hour fire-resistance rated assembly, R302.3. Provide a detail or notation showing compliance with separation from floor to roof. 4. Clarify the roof framing plan, sheet A-07. Show a beam size and column location if a porch is included, R301.1. SECTIONS - DETAILS: 1. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). 2. Clarify the placement of ceiling/roof insulation for the attic ventilation for each dwelling as the attic space requires a fire barrier between units, R806. 3. Notate and specify a complete roofing system: Roof sheathing, size (1/2” OSB or plywood) and method of installation (moisture barrier, flashing, etc.), R905. PLUMBING PLANS: 1. Replace the UPC reference with the adopted code IRC. 2. The Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate water meter size for the additional demand. 3. Show an individual accessible water supply shut-off valve for each dwelling unit, P2903.9.1. 4. Show an individual accessible drain clean-out for each dwelling unit, P3005.2. MECHANICAL PLANS: 1. Provide a mechanical plan, R301.1. 2. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1. 3. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Identify the device model number providing an adjustable setting and note the minimum continuous setting. A two or three-bedroom dwelling under 1501 SF requires a 45 CFM continuous setting. A one-bedroom dwelling under 1501 SF requires a 30 CFM continuous setting. ELECTRICAL PLANS: 1. Remove the APS reference from the service panel note. 2. Update the Riser Diagram showing a dual pack meter base located with TEP coordination, NEC 225.30 and E3403. 3. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3 OUTDOOR LIGHTING CODE 1. Provide full cut-off FCO style fixtures or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining compliance within exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 11/12/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1125-05349 Location: 2852 E VIA BARTOLOME Review Date: 11/12/2025 Site Engineering Comments: 1. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/ 2. The North Arrow will need to be reoriented to be accurate. 3. The final plat for Rancho Reyes subdivision calls shows a 6 foot private utility easement along the front property line and road way, please show and call out this easement. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 11/13/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-1125-05349 2852 E Via Bartolome, Tucson, AZ 85706 Residential ADU – Casitas (1st Review) TRANSMITTAL DATE: November 13th, 2025 This site is located in the R-1 zone (UDC 4.7.8). An accessory dwelling unit is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 8 & 9 and 6.6.3. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The scale of the site plan appears to be incorrect. 2. (Comment) The front and side setbacks listed under Zoning Information appear to be incorrect. 3. (Comment) See residential engineering comments regarding the Inclusive Home Design Ordinance accessible route. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 11/07/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |