| 11/27/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1124-06876 (2015 E HELEN ST TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC) 1. For the ¾ inch CSST pipe, provide the manufacturer’s specifications showing the product type and EHD or use EHD 23 in Table G2413.4(5) for Corrugated Stainless Steel Tubing. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. 2. Per EHD 23 and the given demand, the 3/4" CSST pipe is undersized. |
||