| 11/26/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/26/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1124-06847 (6928 S 6TH AV TUCSON, AZ 85756) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. 1. Note and specify all piping materials, P2609, 2903.1. 2. Provide the water pipe diameter between the meter and the shut off valve in compliance with P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units. 3. Non-metallic water line requires a blue tracer line. 4. Minimum burial depth, 12”, P2603.5. 5. Each address requires it's individual permit. This permit is for the identified main address 6928 S 6TH AV TUCSON, AZ 85756 only, please start new permits for all other addresses/units. |
||
| 11/25/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |