Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1124-06837
Parcel: 11450004L

Review Status: Requires Resubmit

Review Details: RESIDENTIAL FENCE/WALL v.1

Permit Number - TC-RES-1124-06837
Review Name: RESIDENTIAL FENCE/WALL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/29/2024 Light Residential Building Review (OIP) APPROVED
12/17/2024 Site Zoning APPROVED
12/17/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/11/2024 Site Engineering REQUIRES RESUBMIT 1. This project is located in a FEMA Zone AE regulatory floodplain and requires a floodplain use permit. The CMU walls require a drainage opening at grade level at a minimum distance of 5 feet apart. The gates must be elevated 6 inches above grade. Show these specs on the revised plans and submit the plans for the floodplain use permit as well as the resubmittal for this wall permit.

Mike Ortiz
michael.ortiz@tucsonaz.gov
11/26/2024 PDSD Application Completeness Express REVIEW COMPLETED