Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1124-06794
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/30/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/11/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-1124-06794 (1991 W SAN JUAN TR TUCSON, AZ 85713) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), International Building Code (IBC). Special Inspection: 1. Please provide Special Inspection Certificate with Part A, and Part B, completed with next submittal. IBC 107.2.1. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf 2. Special inspections required per General Structural Notes #10 on sheet S1: Field Welding. Post-Installed Anchors as required. Plumbing: 1. Update Keyed Notes #4 on sheet 1 to show ¾” water line to the new accessory building. It should be consistent with sheet EP1 Plumbing Plan. 2. Show the connection of the new accessory building sewer line to the existing sewer line. Include the existing sewer line size. Electrical: 3. Provide electrical load calculations for the main 400A service panel, E3602.2. 4. Show the 200A sub-panel feeder conductor size/type and over-current protection (breaker size), E3705.5. 5. Show all garage/accessory buildings 120-volt receptacle outlets 15 & 20 AMP with GFCI protection, E3902.2. Include the ceiling receptacles on circuit #7. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 12/23/2024 | Site Engineering | REQUIRES RESUBMIT | TC-RES-1124-06794 1991 W SAN JUAN TR 1. Because this is in an Environment Resource & Hillside Development Zone a grading permit is required. a. The grading permit is a separate development package and should show ACS (Average Cross Slope) calculations per TSM 9-01.3.0 and UDC 5.2.5. b. Please show area of disturbance and clearing & grading on plans. Tucson codes and ordinances can be found online at: https://codelibrary.amlegal.com/codes/tucson/latest/overview Chris Arrington chris.arrrington@tucsonaz.gov |
||
| 12/24/2024 | Site Landscape | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: 24 X 30 STEEL BUILDING AS ACCESSORY STRUCTURE ACTIVITY NO: TC-RES-1124-06794 ADDRESS: 1991 W SAN JUAN TR ZONING: R-1 RESIDENCE ZONE, ERZ, HDZ LAND USE: ACCESSORY STRUCTURE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape/NPPO Section review comments have been addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Per Site Engineering comments with regard to providing a development package for the grading permit due to the site being in the Hillside Development Zone and Environmental Resource Zone. Per UDC 5.2. HILLSIDE DEVELOPMENT ZONE (HDZ): Add the following Notes to the cover sheet: VEGETATION RETENTION AND REVEGETATION a. Vegetation Retention (1) Existing viable and transplantable trees with four inch or greater trunk diameter and cacti shall be preserved in their original locations, except for building sites and access and utilities serving building sites. (2) When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti shall be salvaged and replanted in areas requiring revegetation, whenever possible. b. Revegetation All cut or fill slopes that are no steeper than three horizontal to one vertical and all utility trenches or septic leaching fields that are not located in parking or driveway areas shall be revegetated in compliance with the following standards: (1) All plants used in revegetation shall be the same as the native vegetation on the site prior to grading or clearing or any adjacent site; and, (2) Revegetation shall be accomplished with the following minimum standards for plants: (a) Desert trees, a minimum of 15-gallon size with a minimum trunk diameter of two inches measured at the soil level, or large specimen cactus shall be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading; and, (b) Seeds for trees, desert shrubs, and grasses shall be planted with a density adequate to control erosion and may use one of the following methods of planting: Raked into the soil with appropriate mulch materials; hydroseeding; anchored mulches; or established on jute, rolled straw, or similar material. Another method may be approved by PDSD. (3) A temporary watering system shall be installed until the revegetation materials are established. 3. Slope Stabilization All slopes steeper than a ratio of three horizontal to one vertical, with the exception of retaining walls, shall be stabilized with properly engineered stone riprapping or sculptured rock as follows: a. Stone riprapping shall be hand-placed on the slope; b. The stabilizing material used shall blend with the natural appearance of the site or lot and the surrounding terrain; and, c. Vegetation retention and revegetation should be used in conjunction with riprapping. 2. There is an ERZ wash near the southeast portion of the proposed building. Based on the proposed plan, there is no encroachment into the ERZ wash located on site. Provide protective fencing between the development and the wash prior to construction to prevent disturbance in the wash. 3. Provide a NPPO or a NPPO Waiver for the work being proposed on site. If there are protected native plants, and they will not be disturbed, then the NPPO Waiver will be sufficient for review and approval of the project. If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov |
||
| 12/30/2024 | Site Zoning | REQUIRES RESUBMIT | See comments from Site Engineering and Site Landscaping. Final Site Zoning approval of this plan is contingent upon submittal and approval of the required development package first. | ||
| 11/22/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |