Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-1124-06734
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/05/2025 | Residential Building - Standard | REQUIRES RESUBMIT | Provide a complete construction plan set showing 2018 IRC and City of Tucson building ordinance compliance after DDO approval. | ||
| 02/21/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando García Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-1124-06734 – Residential Building 7771 E Lester St, Tucson, AZ 85715 Building Plan Review (2nd Review) TRANSMITTAL DATE: February 21, 2025 This site is located in the R-1 zone (UDC 4.7.8). A detached single-family dwelling is a permitted use in this zone. 1. (Comment) The minimum required setback in an R-1 zone is the greater of 6’ or 2/3 the height of structure wall. Height is measured from design grade. The submitted plans appear to measure the height of the addition’s walls from finished floor elevation, rather than design grade. Please provide a height calculation from design grade. Assuming 4” to 6” in addition to the provided heights, at 8’ 4” to 8’ 6” tall, the minimum required setback to the western property line is 6’. 3’ 0” is shown. A Design Development Option (DDO) is required to be processed and approved to allow this reduced setback. 2. Final Site Zoning approval of this permit cannot occur until the DDO application is processed and approved and the follow-on two-week appeal period is over. Provide a copy of the approved DDO decision letter as an attachment to the resubmittal of this permit. 3. (Comment) See additional comments from the DDO Reviewer, Mark Castro. SUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site and build plan set with a detailed comment response letter, which states how all Site Zoning Review Section comments were addressed. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 02/13/2025 | Zoning Modifications - DDO | REQUIRES RESUBMIT | The submitted DDO application cannot be accepted at this time. Please address the following and resubmit the application. 1) Submit a complete floorplan of the existing residence with the new addition. If you have any questions, email Mark.Castro@tucsonaz.gov |
||
| 02/05/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |