Permit Number: TC-RES-1124-06730
Parcel: 136331990

Address:
9435 E 33RD ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW REVISION v.1

Permit Number - TC-RES-1124-06730
Review Name: RESIDENTIAL SIMPLE REVIEW REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/03/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Permit Review TC-RES-1124-06730 (9435 E 33RD ST TUCSON, AZ 85710)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).


1. Provide a complete Revision Letter detailing the scope of work for this revision.
2. Additional comments may be forthcoming depending on scope of work change..

3. Hallways of 10’ or more in length require a receptacle, E3901.10. Provide a minimum of one receptacle in the hallway between the master bedroom and the study.
4. Show receptacle outlets at each kitchen counter space wider than 12” with no point along the wall line more than 24” from a receptacle outlet, NEC 210.52(C)(1). Show receptacles within 2’ of counter edges or corners and no more than 4’ apart.


Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
02/28/2025 PDSD Application Completeness Express REVIEW COMPLETED