Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1124-06669
Parcel: 117022780

Address:
921 N 2ND AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-1124-06669
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/31/2024 Site Engineering NOT REQUIRED
12/04/2024 Site Landscape NOT REQUIRED
01/13/2025 Bldg Permits - Post Review PENDING ASSIGNMENT
01/13/2025 Historic REQUIRES RESUBMIT Staff has reviewed your application and deemed incomplete.
Attached is a link on how to get to the sub-record.
https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf
Alternatively, the following resource will help you apply for the sub-record: sub-records.pdf
Once you have it submitted under the sub-record, please let me know.
If you have any questions, contact Michael.Taku@tucsonaz.gov
12/17/2024 Residential Building REQUIRES RESUBMIT Provide a complete construction plan set showing 2018 IRC and City of Tucson building ordinance compliance after historic approval.
01/07/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Fernando García
Planning & Development Services Department – Zoning Review Section

PROJECT:
TC-RES-1124-06669 – Residential Building
921 N 2nd Av, Tucson, AZ 85705
Building Plan Review (1st Review)

TRANSMITTAL DATE: January 7, 2025

This site is located in the NR-2 zone (UDC 4.7.9). A parcel developed with a duplex is permitted one accessory dwelling unit (ADU) subject to UDC Article 6.6.3.B

1. (Comment) Provide the square footage dimensions for each of the duplex’s two dwellings and draw on the site plan.

Per UDC Article 6.6.3.B.5, an ADU is limited to 75% of the gross floor area (GFA) of the principal dwelling, but no larger than 1000 sf. It can be a minimum of 650 sf regardless of the size of the principal dwelling.

When an ADU is proposed for a parcel developed with a duplex, the principal dwelling is whichever one of the two duplex dwellings the owner chooses as the principal dwelling. The entire duplex does not count as the principal dwelling.

In this case, it appears that the proposed ADU is larger than what is permitted and will need to be reduced in size.

2. (Comment) This property is within the West University Neighborhood Preservation Zone.

As such, a “Special Districts” application to request the required design review. Access the design manual for West University at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/historic-preservation/documents/wuhzabguides7.22.15final.pdf

Access the Special Districts application at: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf. Submit the application on next submittal.

Final Site Zoning approval of this permit cannot be granted until the NPZ Design Review process is complete.

SUBMITTAL OF THE FOLLOWING IS REQUIRED: NPZ special districts application. Site plan set with a detailed comment response letter, which states how all Site Zoning Review Section comments were addressed.

If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov.
12/04/2024 PDSD Application Completeness REVIEW COMPLETED