Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1124-06647
Parcel: 127032370

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-1124-06647
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/21/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1124-06647 (5607 E HAWTHORNE ST TUCSON, AZ 85711)

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response letter addressing the comments below maybe be delayed until the response letter is received.
1. Location of the electrical panel is not clear. Show exact location of the meter/panel to be upgraded.
2. Aerial views and your site plan of the property show the overhead service conductors will be passing over the finished and unfinished portion of the roof. Please indicate that the overhead service conductor over the the "Roofline" requires an 8’ clearance above the roof, E3604.2.1. The 8’ clearance is required to be maintained for a distance of 3’ from the edge of the roof. For questions: Building_Official@tucsonaz.gov
11/21/2024 PDSD Application Completeness Express REVIEW COMPLETED