Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1124-06641
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/13/2024 | Site Engineering | NOT REQUIRED | |||
11/22/2024 | Site Landscape | NOT REQUIRED | |||
12/19/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/27/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-1124-06641 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Show the code reference on the plans. Place all pages into a single plan set file. Number the pages. Provide a response letter on separate file when submitting the updated construction plan set. Provide a clear and concise construction plan set. Review the sample drawings for the Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Indicate the location of any existing overhead electrical line, R106.1.1. Show the utility lines requiring relocation. STRUCTURAL PLANS: 1. Provide a Roof Framing Plan showing the beams sized for supporting live and dead structural loads (Table R602.7(3)). Update to 4”x8” beams. SECTIONS - DETAILS: 1 Show the footings with #4 reinforcement and post supported with 1” gap post base hardware, R403.1, R407.3 & R507.4.1. 2 Show roof sheathing and fastening in compliance with Table R602.3 (1). 3 Note the location and size of ledger anchorage to a load bearing wall, R606.11. Remove any stucco behind the ledger. 4 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. ELECTRICAL PLANS: 1. Show any electrical alterations. 2. The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. Check with TEP customer service for service line options. https://www.tep.com/electric-service-requirements If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
12/19/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-1124-06641 6472 E VIA JARDIN VERDE – PAD-1 Attached Covered Porch (1st Review) TRANSMITTAL DATE: December 19, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in PAD-7 (UDC 4.7.24). A single-family residence is a permitted use in the PAD. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. Zoning recommends that you use the plot plan issued for construction of the dwelling found at: https://pro.tucsonaz.gov/permitdetails/T21CM09515/, and provide the following information on the plot plan. a. Show the proposed porch cover and provide setback dimensions. b. Provide the owners name on the plot plan. c. Provide the legal description, “LA ESTANCIA DE TUCSON LOT 238” on the plot plan. d. Indicate the zoning of this parcel and all adjacent parcels on the plot plan. The zoning should be PAD-7 for this parcel and all adjacent parcels. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
11/14/2024 | PDSD Application Completeness | REVIEW COMPLETED |