Review Date Reviewer's Name Type of Review Description Status Comments
11/27/2024 Residential Building APPROVED
12/13/2024 Site Engineering NOT REQUIRED
11/22/2024 Site Landscape NOT REQUIRED
12/19/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/19/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-1124-06640
55 E CALLE DE FELICIDAD – RX-2
Detached Carport (1st Review)

TRANSMITTAL DATE: December 19, 2024

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence is a permitted use in this zone (Table 4.8-1.

1. Per UDC Table 6.3-1.A the minimum setback to the interior property lines are 20’-0”. Perimeter yard setbacks for a carport structure are measured from the post supporting the structure as long as the roof overhang is not greater than 2’-0”, UDC Articles 6.4.5.B.2 & 6.4.5.D.1.b. Based on the 3’ overhang shown the proposed setback from the carport to the north property line is 10’-6” and based on a 1’ overhang the proposed setback to the east property line is 14’-7”. At a minimum, a neighbors setback waiver is required. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________
If you are not able to secure this waive a Design Development Option (DDO) will need to be submitted and approved or relocate the show to meet the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
11/14/2024 PDSD Application Completeness Express REVIEW COMPLETED