Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1124-06578
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/11/2024 | Design Review | NOT REQUIRED | This is not an IID project. | ||
| 11/22/2024 | Site Landscape | NOT REQUIRED | |||
| 12/18/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/02/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-1124-06578 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. Separate the submitted pages with construction plans and support documents in different files. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLANS: 1. Show the functional name of each existing adjacent room, R106.1.1. Existing bedrooms with altered exterior openings must show code compliance for egress directly to the exterior, R310. Include any alteration of door or window openings between the proposed AZ room and the room to the south. A new window at the east wall may be required. SECTIONS – DETAILS – NOTES: 1. Clarify keynote #1 sheet A.2 with the garage indication. ELECTRICAL PLANS: 1. TEP requires unobstructed access to the utility meter. Show an appropriate location for the service panel. 2. Show the location of both Panel A & B on the plan. 3. Interior alterations require the installation of smoke alarms in existing bedrooms, R314.2.2. Provide notation if the smoke alarms exist or are proposed. 4. Show a 20 AMP branch circuit on the panel schedule for the clothes washer; this circuit may not serve other locations, E3703.3 and 3901.8. 5. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 12/12/2024 | Site Engineering | REQUIRES RESUBMIT | TC-RES-1124-06578 222 N 1ST AV Site engineering comments are as follows: 1. This project is situated directly adjacent to a FEMA regulated floodplain. Please delineate the floodplain border on the site plan to ensure that this project is safely outside. Any encroachment into the floodplain will require a floodplain use permit. Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 12/18/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-1124-06578 222 N 1st Avenue Tucson, AZ 85719 Enclose patio to dining room/laundry and Arizona room, pergola addition (1st Review) TRANSMITTAL DATE: 12/18/2024 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. 2. Comment: Please label the surrounding properties zoning classification as noted in the sample site plan. 3. Comment: Please draw, label, and dimension the half right of way to the face of curb and from the face of curb to the property line along N. 1st Avenue. Please refer to Paving Plan I-408 if necessary. https://maps-and-records.tucsonaz.gov/construction-plans/details/I-408. 4. Comment: The North symbol is incorrectly labeled on your site plan as it is pointing East. Please update. 5. Comment: Please clearly draw, label, and dimension the vehicular use area on the site plan. 6. Comment: Per UDC 6.4.3.C.1, “Roofed areas, open on at least one side, which provide shelter to exterior areas such as balconies, entrances, stoops, and terraces, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking are excluded from lot coverage calculations.” Please remove the proposed front porch from your lot coverage calculations and update the calculations. 7. Comment: The maximum height in the R-2 zone is 25’. Please update your height restrictions as currently they say maximum height can be 34’. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 11/13/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |