Permit Number: TC-RES-1124-06574
Parcel: 110091980

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-1124-06574
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/14/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/14/2024 Historic PENDING ASSIGNMENT
11/14/2024 Light Residential Building Review (OIP) PENDING ASSIGNMENT
11/14/2024 PDSD Application Completeness Express REQUIRES RESUBMIT Permit Review TC-RES-1124-06574 (2861 N BEVERLY AV TUCSON, AZ 85712)

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC)

1. The overhead service conductor over the detached structure requires an 8’ clearance above the roof, E3604.2.1. The 8’ clearance is required to be maintained for a distance of 3’ from the edge of the roof. Show the mast height required to achieve the necessary clearance.

Here are the Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf