Review Date Reviewer's Name Type of Review Description Status Comments
12/10/2024 Site Engineering NOT REQUIRED
11/22/2024 Site Landscape NOT REQUIRED
12/16/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/27/2024 Residential Building REQUIRES RESUBMIT TC-RES-1124-06490
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Provide a response letter on separate file when submitting the updated construction plan set.

SITE PLAN:

1. Indicate the location and dimension of the proposed building and existing overhead electrical line, R106.1.1. Show the utility lines requiring relocation.

STRUCTURAL PLANS:

1. Show the size and location of each support footing, R106.1.1.
2. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. Prefab structures have engineered plans available form the supplier which are included with the submitted site plan.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
12/16/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-1124-06490
1313 N Sahuara Ave Tucson, AZ 85712
Detached carport (1st Review)

TRANSMITTAL DATE: 12/16/2024

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference.
2. Comment: Clearly draw, label, and dimension the property lines. Please refer to the sample site plan if needed.
3. Comment: Please include the lot coverage calculations on the site plan including the vehicle use area.
4. Comment: Please include the legal description on the site plan. The legal description should read “Mountain View Acre Farms N62.50’ S162.50’ Lot 10 Blk 8”.
5. Comment: Please draw, label, and dimension the half right of way to the face of curb and from the face of curb to the property line along N. Sahuara Avenue. Paving plan I-843 shows the dimensions as 22’ from the centerline to the face of curb and 8’ from the face of curb to the property line.
6. Comment: Please draw, label, and dimension setbacks from the proposed detached carport to all property lines.
7. Comment: Please label the surrounding property zoning classifications on your site plan. This property is surrounded by R-1 zoning.
8. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and updated plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
11/07/2024 PDSD Application Completeness Express REVIEW COMPLETED