Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1124-06440
Parcel: 136173110

Address:
3318 S MORMON DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-1124-06440
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/06/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review (TC-RES-1124-06440 3318 S MORMON DR TUCSON, AZ 85730)

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide an updated Plan and a written response letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response letter addressing the comments below maybe be delayed until the response letter is received.

1. Clarify the scope of work being performed on your gas piping template, R106.1. Highlight the portions of the line being new or replaced.

2. Clarify if the 3/4'' Pipe size coming directly out from meter is the meter size or a segment of pipe that is 3/4" then branching up to the 1'' pipe. This segment requires 1" per Table G2413.4(1).
11/06/2024 PDSD Application Completeness Express REVIEW COMPLETED