Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-1124-06437
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/09/2024 | Site Engineering | NOT REQUIRED | |||
| 11/12/2024 | Site Landscape | NOT REQUIRED | |||
| 12/16/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/27/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-1124-06437 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Provide a response letter on separate file when submitting the updated construction plan set. Provide a clear and concise construction plan set. Review the sample drawings for a the Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Indicate the location of the property lines, proposed building and existing overhead electrical line, R106.1.1. Show the utility lines requiring relocation. SECTIONS - DETAILS: 1 Provide the detail or remove unnecessary reference indicators such as 3/S4.2, 8/S4.1, 9A/S4.1 and 14/S4.1 from the Foundation Plan. 2 Provide the detail or remove unnecessary reference indicators such as 1/S5.2, 3/S5.3, 5/S5.2, 6/S5.1, 17/S5.3, 17/S6.1 and sheet S2.1 from the Floor Framing Plan. 3 Show the size of roof sheathing and fastening in compliance with Table R602.3 (1) or note open joist without sheathing loads. 4 Note the location and size of anchorage to a load bearing wall, R606.11. 5 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity located at each end of the rafters, R802.11 amended. ELECTRICAL PLANS: 1. Show any electrical alterations. 2. The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. Check with TEP customer service for service line options. https://www.tep.com/electric-service-requirements If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 12/16/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-1124-06437 7018 S Sweetbush Ave Tucson, AZ 85756 Porch (1st Review) TRANSMITTAL DATE: 12/16/2024 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Site zoning is unable to conduct a full review with the submitted documents. Please include a site plan in your next submittal which includes the information noted in the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. 2. Comment: Additional comments might be forthcoming depending on the updated plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 11/06/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |