Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1124-06431
Parcel: 133311330

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-1124-06431
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/05/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/05/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1124-06431 (8812 E MCCLELLAN ST TUCSON, AZ 85710)

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.

1. Moving the location of the Gas Meter may cause existing gas pipe systems to become undersized and could require additional modifications to be code compliant, G2412.3.
2. Provide a complete gas piping template showing the connection and length from the meter to all attached appliances, G2401.1, R301.1: Include pipe size, type (Black Iron, Poly) and length. Provide appliance demands, G2413.4.1. Connection must be shown to all appliances.
11/05/2024 PDSD Application Completeness Express REVIEW COMPLETED