Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-1124-06373
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/04/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/04/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) Polyethylene Plastic Pipe. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. The ¾” and 1/2" pipe to the shown appliances is undersized for the overall length(80’) and appliance demands(275,000BTU). Please resubmit with corrections. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 11/04/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |