Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: In Review
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1124-06361
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: In Review
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/12/2024 | Site Landscape | NOT REQUIRED | |||
N/A | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
N/A | Historic | PENDING ASSIGNMENT | |||
N/A | Site Engineering | PENDING ASSIGNMENT | |||
N/A | Site Zoning | PENDING ASSIGNMENT | |||
11/19/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-1124-06361 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Note the 2018 IRC reference on the plans. Provide a response letter on separate file with the updated construction plan set. SITE PLAN: PLANS: 1. Clarify if repairs include the replacement of truss or rafter structural components, R301.1.3. Provide proposed rafter sizes and spacing in compliance with Table R802.4. 2. Show a minimum structural sheathing thickness in compliance with, R803.2.2 and Table R503.2.1.1(1). 3. Identify the roof covering material in compliance with R903. 4. Show the location of venting devices requiring replacement. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
11/04/2024 | PDSD Application Completeness | REVIEW COMPLETED |