Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1123-09781
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/29/2023 | Site Engineering | NOT REQUIRED | |||
| 12/29/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/14/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-1123-09781 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. FRAMING PLAN: 1. Provide complete roof framing plan showing the size of the proposed garage ridge beam, R301.1. Also, clarify the location of the bearing point of the beam at the interior end. Show if the existing support post will remain or if the proposed garage beam will replace the existing carport beam. ELECTRICAL PLANS: 1. Garage Receptacle Location: a 20 AMP receptacle outlet is required at each vehicle bay not more than 5.5 feet above the floor, E3901.9. Show if proposed or existing. 2. Show an exterior switch-controlled light at the proposed garage doorway, E3903.3. 3. Show the exterior Ramada receptacle outlet with GFCI protection, E3902. OUTDOOR LIGHTING CODE Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 12/13/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-1123-09781 1111 S CARNEGIE DR- R-1 ADD A STORAGE WITH A PORCH ATTACH AND EXTEND CARPORT- (1st Review) TRANSMITTAL DATE: December 13, 2023 Provided a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. The plans state “EXTEND CAR PORT AND CONVERT GARAGE”, clarify what you are converting the garage to. If this conversion is for a habitual space provided a full floor plan of the entire house so that it can be determined if the requirements of UDC Article 4.9.7.B.7 apply. 2. Based on aerial photos the porch called out at the northwest corner of the house shows up some time after 2008. Zoning was not able to find approved permit documents for the porch. Either provide approved permit documents or include the porch in this permit. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 12/04/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |