Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1123-09635
Parcel: 114551880

Review Status: Requires Resubmit

Review Details: RESTAMP - RESIDENTIAL v.1

Permit Number - TC-RES-1123-09635
Review Name: RESTAMP - RESIDENTIAL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/04/2024 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-RES-1123-09635
10154 E WINDING TR Zoning RX-1

TRANSMITTAL DATE:‎January 4, 2024


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: The proposed sleeping quarter will exceed 12ft in height, please revise the height of the sleeping quarters. Per UDC section 6.6.3.D “Accessory structures , except for accessory dwelling units , shall not exceed 12 feet in height, unless attached to a principal structure . If attached to the principal structure , maximum height permitted shall be the same as for the principal structure”
6.4.4.A. Building height is the vertical distance measured from the design grade elevation to the highest point of a flat roof; to the deck line of a mansard roof; or to the middle (between the eave and ridge ) of the highest gable of a pitched or hipped roof, except as follows: (See Figure 6.4.4-A, Measurement of Building Height .)




If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov