Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1123-09538
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/05/2023 | Residential Building | APPROVED | |||
12/14/2023 | Site Engineering | NOT REQUIRED | |||
11/21/2023 | Site Landscape | NOT REQUIRED | |||
12/19/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
12/19/2023 | Historic | REQUIRES RESUBMIT | Property is listed as a contributor to the West University Historic Preservation Zone and work requires review by the West University Historic Zone Advisory Board (WUHZAB) and the Plans Review Subcommittee (PRS). Additions should be differentiated from the original construction, consider modifying the stucco texture. Plans should note the material of the windows and doors. Please submit the documents noted under a Full Review on page 2 of the Historic and Special District informational handout (https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf). The documentation should be submitted under the Historic sub record. Questions? Contact Jodie Brown at jodie.brown@tucsonaz.gov |
||
11/30/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-1123-09538 1839 S. Olsen Av. – HR-2 Addition (1st Review) TRANSMITTAL DATE: November 30, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the HR-2 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof. As a height dimension from design grade to the highest point of the north wall of the proposed addition Zoning cannot determine the required perimeter yard setback from the addition to the north property line. Based on a measurement using our review Bluebeam software, it appears that the wall height is approximately 10’-11” which would require a 7.28 perimeter yard setback to the north property line, proposed setback is 6.0’. As Historic review is required for this project, Historic review may approve reduced setbacks. If Historic does not approve the reduced setback a A Design Development Option (DDO) must be submitted and approved. COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). 2. As you propose and addition to a dwelling located in the HR-2 zone Historic review is required and must be approved prior to approval of this building plan. Historic application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Historic-Preservation If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
11/17/2023 | Fire New Construction | REVIEW COMPLETED | |||
11/17/2023 | PDSD Application Completeness | REVIEW COMPLETED |