Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1123-09424
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/04/2023 | Site Engineering | NOT REQUIRED | |||
| 12/04/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/28/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-1123-09424 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. SITE PLAN: 1. Identify utility lines requiring alterations, R106.1.1. 2. Show the square footage of the addition and covered patio. 3. Provide an Electrical Site Plan showing an underground service entrance or an overhead line with 8-foot clearance above the proposed roof, E3604.2.1. STRUCTURAL PLANS: 1. Provide complete structural (roof framing) plans showing compliance with the IRC or provide an Arizona structural engineer plan set showing performance compliance, R301.1. Show the roof slope. Design roof structural members that support rafters as beams when the roof pitch is less than 3” to 12”, R802.3. Show roof structural members with rafter ties (or ceiling joists) and collar ties (ridge straps) when the roof pitch is equal or greater than 3” to 12”, R802.3. SECTIONS - DETAILS: 1. Show a complete cross-section detail of the new exterior wall, R106.1.1. Show with dimensions the exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts providing 7” embedment into concrete or masonry, R403.1.6. 2. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Show roof or ceiling insulation at detail #1/4. 3. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. MECHANICAL PLANS: 1. Show combustion air compliance for appliances in confined spaces with two interior area openings of 1 SQ IN for each 1,000 BTU rating and minimum of two 100 SQ IN openings, one within 12” of top and other 12” of bottom, G2407.5.3.1. ELECTRICAL PLANS: 1. Show the mast height on an electrical riser diagram providing 8’ clearance above the Porch roof, E3604.2.1. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 11/29/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-1123-09424 641 South Bryant Avenue – R-1 Addition (1st Review) TRANSMITTAL DATE: November 29, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Show the square footage of the lot, the existing dwelling, the proposed addition, the accessory structures, and total under roof area on the site plan. 2. Provide a lot coverage calculation on the site plan. Lot coverage includes the area of the site covered by buildings, outdoor storage areas, and vehicular use areas, whether paved or unpaved (UDC 6.4.3.B.3). Roofed areas that are open on at least one side such as porches and patios are not included within the lot coverage calculation (UDC 6.4.3.C.1.a). Lot coverage shall not exceed 70% in the R-1 zone (UDC Table 6.3-2.A). 3. Show all accessory structures on the site plan. Two detached accessory structures to the north of the existing dwelling appear in aerial photography as early as 1998. Clarify if these structures are to remain or be removed. A shade sail also appears along the south lot line in 2018 and is required to meet perimeter yard setbacks. As a zero-foot setback is proposed for this shade sail, a Board of Adjustment variance is required to be granted to allow the shade sail to remain. Indicate whether the shade sail will remain or be removed. Additionally, the “existing shed” depicted on the site plan appears in aerial photography in 2022. Per UDC 6.3-2.A, when a residential use is adjacent to a residential zone, the required interior perimeter yard setbacks are 6’-0” or 2/3 the height of the exterior wall, whichever is greater. Provide the height of the north and east exterior walls of the existing shed. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 11/13/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |