Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-1123-09380
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/12/2023 | Site Engineering | NOT REQUIRED | |||
| 12/12/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/30/2023 | Residential Building | REQUIRES RESUBMIT | 1. Provide a site plan showing dimensions of buildings and utilities, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. Identify utility lines requiring alterations, R106.1.1. 2. A manufactured assembly (pre-built) requires an engineer stamped plan set showing a performance designed structure based on the engineer's calculations. |
||
| 11/28/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-1123-09380 9255 East Wrightstown Road – SR Barn/garage (1st Review) TRANSMITTAL DATE: November 28, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Provide a site plan meeting the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. Ensure all existing and proposed structures are depicted on the site plan with all required information. 2. Per Tucson Unified Development Code (UDC) 6.4.4.A, building height is the vertical distance measured from the design grade elevation to the middle (between the eave and ridge) of the highest gable of a pitched roof. Provide a measurement from the design grade elevation to the middle of the pitched roof with your next submittal. Please note that accessory structures such as proposed shall not exceed 12 feet in height, unless attached to a principal structure (UDC 6.6.3.D). A Board of Adjustment variance is required to be granted to allow the height of the proposed structure to exceed 12 feet. 3. Per UDC 6.6.3.E, the total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement. Ensure that calculations are provided to determine whether the gfa of all accessory structures exceed 50% of the gfa of the existing residence. A Board of Adjustment variance is required to be granted to exceed the requirements of this standard. Contact Mark.Castro@tucsonaz.gov should you have questions about the DDO process. 4. Please note that further Zoning comments may be forthcoming based on submittal of the required site plan. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 11/16/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |