Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL POOL v.1
Permit Number - TC-RES-1123-09357
Review Name: RESIDENTIAL POOL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/13/2023 | Site Zoning | NOT REQUIRED | |||
| 11/14/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/14/2023 | Residential Building | REQUIRES RESUBMIT | Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. COMMENTS: 1. Show compliance with the pool enclosure barrier requirement by including a continuous 5 foot barrier around the pool, ARS 36-1681. - label the existing fence as fence with heights. Show the gate(s) with the swing direction on the plot plan. 2. Notate and specify all piping materials on the plot plan, P2608. 3. Bond the perimeter surface and reinforcing steel as required by ISPSC 302.1 and NEC680.26(B)(2). 4. Show the distance between the house and the pool on the plot plan. 5. Show compliance with the pool barrier from a dwelling by including a UL 2017 listed pool alarm system for doors and windows open to the pool, or show a continuous barrier around the pool, 2018 ISPSC 305.4.1. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov |
||
| 11/09/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |